A good site survey decides three things: how big the system can be, what it will cost to install, and whether anything will cause trouble later. Miss one detail (a staircase room's shadow, a three-phase meter, a 40 m cable run) and the quotation is wrong, the margin disappears, or the customer is unhappy.
Use this checklist on every visit. It takes 20–30 minutes once your team is used to it.
1. Customer and electricity details
- Name, phone and WhatsApp number, and who will decide (owner, family member, society committee)
- Last 6–12 months of electricity bills (photograph at least the latest one)
- Consumer number and DISCOM name
- Sanctioned load (kW) and supply type: single phase or three phase
- Average monthly units and the highest month (summer)
- Is there a DG set or an inverter/UPS already?
The sanctioned load matters: for net metering, many DISCOMs limit the solar size to the sanctioned load. If the customer needs more, a load enhancement application comes first.
2. Roof measurements
- Roof type: RCC flat, metal sheet, tiled/sloped, or ground mount
- Usable length × width (after leaving space at the edges)
- Which way the roof faces (south is best in India; east/west lose roughly 10–12%)
- Building height (G+ floors), for material lifting and cable length
- Parapet wall height
- Is the roof waterproofed? Any cracks or leakage? (Fix before installation, not after.)
3. Shade
Walk the roof at least once and note everything that casts a shadow:
- Water tanks, staircase and lift rooms, solar water heaters
- Neighbouring buildings and trees (ask whether a building is coming up next door)
- Mobile towers, hoardings, cables
Write down when the shade falls (morning or evening). Morning and evening shade costs much less generation than shade between 10 am and 3 pm.
4. Structure
- Standard low structure, or elevated structure (7–10 ft) so the roof can still be used
- Sheet roofs: purlin spacing and condition, clamp type
- Wind exposure (coastal areas, high floors)
5. Electrical
- Location of the energy meter and the distribution board (DB)
- Where the inverter will go: shaded, ventilated, within reach for the customer
- Cable run from the roof to the inverter and from the inverter to the DB, in metres
- Space for earthing pits (usually three) and the lightning arrester
- Condition of the existing wiring and earthing
6. Practical things
- Water on the roof for panel cleaning
- Access for material: staircase width, lift, crane needed?
- Who keeps the roof key; society permission needed?
7. Photos to take every time
- Full roof (two corners)
- Shading objects
- Electricity meter
- Distribution board
- Inverter spot
- Electricity bill
- A quick line diagram or sketch with dimensions
8. Feasibility
Finish the visit with a clear call: Feasible, Feasible with changes (e.g. elevated structure, load enhancement) or Not feasible, and the recommended size in kW.
Do it on the phone, not on paper
In Nithyam, the solar site survey already has every field above, a photo checklist that shows what is still missing, and a feasibility status. The office sees the survey the moment it is saved, and the quotation can be filled from the system size in one tap.